The test area was designed to maintain a separation between the test area and the laser optics and beam transport area. Access to the test area is via a large target area access door as shown in Figure 2 (details in NIF-1010892837) and is the primary access point for installation and removal of test objects. There is also a top access port that can be utilized for insertion of larger test objects with additional preparation effort. The test chamber dimensions were limited by the available space around the location of CV1 and CV2. The inside volume of the target area is 120 cm x 120 cm with a total height of 250 cm. The top access port is 95 cm x 95 cm. Figure 2 again shows the location of the two disposable debris shields per beam.